JOB DESCRIPTION

Job Description (JD)

Nama ProgramPengoptimuman Operasi IETS [LE-035-4:2014]
Kod CULE-035-4:2014-C02
CompetencyCore
Tajuk CUINDUSTRIAL EFFLUENT TREATMENT SYSTEM PERFORMANCE MONITORING
Penerangan CUIndustrial Effluent Treatment System (IETS) performance monitoring describes the competency required to provide continuous monitoring of compliance parameters for the purpose of effluent permit reporting purposes or simply self-monitoring purposes.

The person who is competent in this CU shall be able to gather monitoring information Industrial Effluent Treatment System (IETS) data, analyse trend of operational data from control and monitoring system, review Industrial Effluent Treatment System (IETS) equipment performance, establish Performance Monitoring Committee (PMC), evaluate system performance of control and monitoring system and prepare performance report of control system and monitoring system.

The outcome of this competency is to ensure the concentration of chemical oxygen demand (COD) and any parameter as specified in the Fifth Schedule, install flow-meters, sampling, monitoring and recording equipment, maintain a record of industrial effluent or mixed effluent discharge monitoring data in the form as specified in the Tenth Schedule in compliance with Operational Industrial Effluent Treatment System (IETS) Environment Quality (EQ) Industrial Effluents Regulation (IER) in 2009 outlined in the Guidance Document on Performance Monitoring of Industrial Effluents Treatment System.
Tempoh Latihan200
Objektif PembelajaranThe person who is competent in this CU should be able to provide continuous monitoring of compliance parameters for the purpose of effluent permit reporting purposes or simply self-monitoring purposes.The outcome of this competency is to ensure the concentration of chemical oxygen demand (COD) and any parameter as specified in the Fifth Schedule, install flow-meters, sampling, monitoring and recording equipment, maintain a record of industrial effluent or mixed effluent discharge monitoring data in the form as specified in the Tenth Schedule in compliance with Operational Industrial Effluent Treatment System (IETS)Environment Quality (EQ) Industrial Effluents Regulation (IER) in 2009 outlined in the Guidance Document on Performance Monitoring of Industrial Effluents Treatment System.
Upon completion of this competency unit, trainee will be able to:-
Gather monitoring information Industrial Effluent Treatment System (IETS) data
Analyse trend of operational data from control and monitoring system
Review Industrial Effluent Treatment System (IETS) equipment performance
Establish Performance Monitoring Committee (PMC)
Evaluate performance of control and monitoring system
Prepare performance report of control system and monitoring system
Pra-Syarat0